Guides / For Vendors
Selling Inspection Equipment to Titanium Shops: What They Need From You

A titanium shop buys inspection equipment on the same terms as any shop: it must measure the tolerances on the drawing, fit the room and the staff, and arrive with proof of accuracy. What titanium changes is a short list: parts that flex under a probe, a material that grows with temperature, alloys that need light-element analysis and surfaces the shop must verify. This guide is for vendors of inspection equipment who want to be useful to a titanium shop, with the numbers from the sources we could open and the places where they stop.
What the material changes for the measuring room
Two property differences from steel affect inspection. The figures below come from Wikipedia for Ti-6Al-4V (citing an ASM data sheet) and AZoM for AISI 1045 steel, so read them as typical, not as a specification.
| Property | Ti-6Al-4V (Grade 5) | AISI 1045 steel |
|---|---|---|
| Elastic modulus | 104 to 113 GPa | 200 GPa |
| Thermal conductivity | 6.7 to 7.5 W/m·K | 51.9 W/m·K |
Titanium’s modulus is about half that of the steel, so a thin wall moves more under the same force. Our thin wall guide shows how this limits what can be cut, and it limits what can be measured too: a probe or clamp that is fine on a steel block can push a titanium web out of tolerance. Titanium’s conductivity is about a seventh of the steel’s, so a part can hold heat from the cut and cool slowly. Wikipedia’s titanium entry gives a thermal expansion coefficient of 9.68 millionths per kelvin at 20 degrees C. On a 100 mm feature, a 1 K temperature error is about 1 micrometre of growth. That is small against a general tolerance and large against a tight one. Our tolerance guide covers which tolerances shops can hold.
The same entry notes that titanium can gall unless tools are sharp and cooling is proper. That matters for gauges as well. Galling is a risk on titanium threads, so ask the shop how it checks them and which gauge finish it prefers. The threading guide covers the cutting side.
Coordinate measuring machines
A CMM is the instrument most shops want to talk about, and the one where vendor claims are easiest to check. Wikipedia’s CMM entry describes touch-trigger probes, scanning probes, non-contact laser and white light systems and optical probes. It says scanning probes drag along the surface and take points at set intervals, and are often more accurate than the conventional touch-probe method and usually faster. It gives touch-probe repeatability within one micron over the measurement volume, and says accuracy is typically given as an uncertainty as a function of distance.
For a titanium shop, ask or offer answers to these:
- What probing force and stylus does the setup use on thin or flexible parts? A scanning head with low contact force may suit a thin wall better than a trigger probe.
- How is the part fixtured? Soft clamps or vacuum fixtures reduce clamp distortion on a part that has just come off the machine.
- What temperature range does the specification assume? Wikipedia’s entry does not state a reference temperature, so quote it from the machine maker’s specification. NIST’s own note on its CMM photo says tight temperature control in the lab will allow improved CMM accuracy, which shows that room temperature is part of the accuracy.
- Is there a verification report to the ISO 10360 series? The entry lists Part 2 for linear dimensions, Part 7 for imaging probing systems and Part 8 for optical distance sensors, and says probes are routinely calibrated against traceable standards.
- Does the software report GD&T features? The entry says measured points can build cylinders and planes to assess roundness, flatness and perpendicularity under GD&T.
If the shop’s parts are small, such as eyewear hinges or watch cases, an optical system may suit better than a touch probe. Wikipedia describes optical probes as a lens and CCD aimed at the point of interest rather than touching the part, which avoids deflection altogether. Say so only where it is true for the feature.
Surface roughness testers
Titanium work often carries a surface requirement. Wikipedia defines Ra as the arithmetic average of profile height deviations from the mean line over the evaluation length, in micrometres or microinches. It says a profile can be measured with a contact profilometer, which uses a diamond stylus, or an optical one, such as a white light interferometer or confocal microscope, and that roughness can also be judged by eye against a comparator sample. ISO 4287 and ASME B46.1 are cited for the definitions, and areal parameters are in ISO 25178. The entry does not give cutoff values, so take those from the standard your customer names.
What a shop wants from a vendor:
- The instrument set to the cutoff and evaluation length the drawing’s standard requires, shown at the demonstration.
- A stylus size and force that will not scratch a polished or anodized surface. Our surface finish guide lists the Ra values shops quote, and the anodizing guide shows why finish changes after a coating.
- A way to measure inside a bore or on a curved feature, because many drawings call for a roughness value there.
- Calibration against a reference specimen, with the specimen supplied.
Need a quote for this part? Get a titanium quote
Positive material identification
Handheld XRF is the usual shop tool for checking an alloy at receiving. An Evident Scientific page says titanium grade identification benefits from direct light-element measurement, that aluminium measurement below 0.5 percent is essential to meaningful aluminium testing, and that analysis takes about two seconds for most alloys. A short test adds expected aluminium as a nominal value, a 20-second test gives a measured aluminium value and direct light-element testing adds 10 to 60 seconds. The same page says XRF measures only elements heavier than sodium, about 10 microns deep, so painted, plated, corroded or peened surfaces may need grinding, and that handheld analyzers are not a full metallurgical certification.
For a titanium shop, those limits matter in practice. Oxygen, carbon and nitrogen are lighter than sodium, so XRF cannot check the interstitial limits that separate Grade 5 from Grade 23. Say so up front. A shop that buys an analyzer on a claim it can sort ELI will learn otherwise at its first audit. Our Grade 23 guide explains the difference, and the heat lot guide shows where PMI fits in a traceability chain.
Other instruments and what to ask first
| Instrument | Titanium question | Evidence to bring |
|---|---|---|
| CMM or scanning probe | Probing force on thin walls, fixturing, temperature | ISO 10360 verification report, probe calibration record |
| Optical or vision system | Small features, burrs, reflective surfaces | Demonstration on the shop’s own part |
| Stylus or optical roughness tester | Cutoff, stylus force on polished surfaces | Reference specimen reading, standard named |
| Handheld XRF | Aluminium measurement, light-element limits | Test time for the grade, stated limits |
| Thread and plug gauges | Galling on titanium threads | Gauge material and finish, calibration certificate |
Penetrant and ultrasonic testing are common buyer requirements, and our guides to FPI and ultrasonic testing of bar describe them from the buyer’s side. Some shops send that work out, so ask whether it is done in house before proposing equipment for it.
How to approach a shop
- Ask what the shop cannot measure today and what that costs in time or scrap. Do not open with a model number.
- Offer a measurement run on the shop’s own titanium part, not a demo piece. A thin, cut-away or small feature shows the limits.
- Quote the accuracy at the size and condition of the shop’s parts, not the best figure on the data sheet.
- Do not claim your instrument meets a customer’s quality rating on the shop’s behalf. We do not make certification claims on this site and neither should a vendor.
- Offer training and a response time you can keep. A broken CMM costs more than the price difference between two.
This site places titanium orders with partner shops that cut them and occasionally asks equipment and material suppliers to check a guide for technical accuracy. Register your company if that is useful to you. There is no fee and no paid placement, and we do not promise introductions or orders.
Sources
- Wikipedia, Coordinate-measuring machine (probe types, scanning, ISO 10360, calibration, GD&T)
- Wikipedia, Surface roughness (Ra, contact and optical profilometers, ISO 4287, ASME B46.1, ISO 25178)
- Wikipedia, Titanium (thermal expansion, thermal conductivity, galling)
- Wikipedia, Ti-6Al-4V (modulus and thermal conductivity, citing an ASM data sheet)
- AZoM, AISI 1045 carbon steel (thermal conductivity and modulus)
- Evident Scientific, handheld XRF for alloy positive material identification (light elements, test times, limits)
- Wikimedia Commons, NIST photo description, Coordinate Measuring Machines
Frequently asked questions
What inspection equipment does a titanium machine shop use?
Most shops measure with calipers, micrometers, gauges and a coordinate measuring machine, check roughness with a stylus or optical instrument and screen material with a handheld XRF analyzer. Which ones a given shop owns depends on its parts. Ask what the shop measures now and where it loses time before you propose a new instrument.
Why does titanium change how a CMM is used?
Titanium has a lower elastic modulus than steel, about 104 to 113 GPa for Ti-6Al-4V against about 200 GPa for AISI 1045 steel, so thin walls deflect more under probe or clamp force. It also expands about 9.68 millionths per kelvin at 20 degrees C. Probing force, fixturing and room temperature matter for tight tolerances.
Can a handheld XRF analyzer check a titanium alloy?
It can help identify the alloy family. An Evident Scientific page says light-element measurement is needed to identify many alloys, that a two-second test uses nominal values and that a 20-second test gives a measured aluminium value. It measures only elements heavier than sodium and about 10 microns deep, so it is not a full certification.
What accuracy proof should an equipment vendor give a shop?
For a CMM, ask for the verification report to the ISO 10360 series for the machine and probe type, and the calibration against traceable standards. Wikipedia's CMM entry lists ISO 10360 parts for linear dimensions, imaging probes and optical distance sensors. For other instruments, supply the calibration certificate and the uncertainty at the size and finish the shop measures.
Need a quote for this part?
Send the drawing. We send one itemised quote for the finished parts and reply within 24 business hours.
Get a titanium quote