How titanium is milled, turned, drilled, threaded and EDM cut, what each grade asks of the tooling and coolant, and the tolerance and finish shops typically hold. Typical figures, never a promise. The shop that quotes confirms what it can hold on your geometry.

Why titanium needs its own process

Titanium is not especially hard. It is difficult because of where the heat goes and how the metal behaves at the edge. Ti-6Al-4V, Grade 5, is the grade most of this page is about, with Grade 2 noted where it differs. Every grade is on the grade reference.

  • Heat stays at the edgeThermal conductivity around 7 W/m K for Ti-6Al-4V and 17 for Grade 2. The chip carries little heat away, so the tool edge runs hot and wears fast.
  • Low modulusGrade 5 sits around 114 GPa, well below steel. Walls and long parts deflect under the cutter and spring back after it passes.
  • Reactive and stickyAt cutting temperature titanium reacts with and welds to the tool. A rubbing edge builds up material, galls threads and hardens the surface it leaves.
  • Fire hazard in finesChips, fines and grinding dust are flammable. Shops that cut titanium routinely manage swarf, coolant and extraction for it.

Process against part feature

Which operation makes which titanium feature, the tolerance it typically holds and what titanium changes in the setup.

ProcessTypical partsTypical toleranceWhat titanium changes
CNC milling, 3 axisBrackets, plates, housings, manifolds±0.05 mm routine, ±0.02 mm with careLow radial engagement and high axial depth. Trochoidal and adaptive toolpaths keep the edge cool.
CNC milling, 5 axisImpellers, blisks, implant bodies, complex fittings±0.02 to ±0.05 mm on positionsFewer setups, shorter tools and a constant tool angle. Often the cheaper route on complex titanium.
CNC turningShafts, hubs, fittings, valve parts±0.02 mm on fitted diameters, ±0.01 mm with careGrade 2 makes long stringy chips. Chip breaker geometry and high pressure coolant control them.
Swiss type turningBone screws, dental implants, pins, small fasteners±0.01 mm on diameters is commonThe guide bushing supports slender parts. Typical route for small medical parts in bar.
DrillingBolt holes, fluid passages, deep holesReamed or bored holes typically H7Through tool coolant and peck cycles. Drilling speeds sit well below milling speeds.
ThreadingFastener holes, fittings, implant threads6H and 6g classes typicalGalling risk on taps. Thread milling or form threads on external features at volume.
Wire and sinker EDMThin slots, sharp corners, hard to reach features±0.005 to ±0.01 mm typical on wireNo cutting force. Leaves a recast layer that fatigue critical parts usually need removed.
GrindingBearing journals, seal surfaces, tight flatnessBelow ±0.01 mm on sizeSpecialist operation. Low stress grinding avoids surface damage and the dust is a fire risk.

Starting cutting data by grade

Starting ranges for carbide from tool supplier titanium data. Every shop sets its own from its machines, tools and the part. Detail in titanium speeds and feeds.

OperationGrade 2 (CP)Grade 5 (Ti-6Al-4V)
Milling, surface speedaround 60 to 100 m/minaround 30 to 60 m/min
Turning, surface speedaround 90 to 140 m/minaround 60 to 90 m/min
Drilling, surface speedaround 25 to 45 m/minaround 15 to 30 m/min
Feed per tooth, end mill0.05 to 0.15 mm0.05 to 0.12 mm
Radial depth, roughing30 to 50 percent of diameter10 to 25 percent of diameter

Tooling and coolant

The decisions that separate a shop that cuts titanium every week from one that quotes it occasionally. More in titanium tooling and coolant and drilling titanium.

  • SubstrateFine grain carbide, high cobalt for toughness. Titanium loads the edge heavily.
  • CoatingAlTiN or TiAlN for roughing, which holds hardness at high edge temperature. Sharp uncoated or thin coated edges for finishing.
  • GeometrySharp edge, positive rake, variable helix around 35 to 45 degrees against chatter, and a corner radius as large as the part allows.
  • FeedA real chip load. A light, timid feed rubs, and rubbing is heat, galling and a hardened surface.
  • CoolantHigh pressure through tool coolant where possible, flood emulsion otherwise. Aerospace and implant specifications often restrict chlorinated cutting fluids, so ask what the shop runs and how it cleans parts.
  • WorkholdingRigid and short. Support thin walls, leave them until last and finish in light passes.

Thin walls, stress and heat treatment

Low modulus and trapped heat make thin titanium walls the fastest way to move a price. Up to about 5 to 1 height to thickness is routine. Above 10 to 1 the shop needs support material, staged removal and possibly a stress relief between roughing and finishing. See thin wall titanium parts.

Heat treatment in air grows an oxygen rich surface layer called alpha case. It is brittle and has to be removed by a finishing cut or chemical milling. If the part is heat treated after rough machining, leave stock for that. Welding and alpha case covers how shops check for it.

Tolerances and finishing

Routine is what shops quote without a conversation. With care adds time and inspection on every piece. Tighter needs a discussion before the drawing is signed. Detail in titanium machining tolerances and titanium surface finish.

FeatureRoutineAchievable with care
General machined dimensions±0.05 mm±0.02 mm
Fitted diameters and bores±0.02 mm±0.01 mm
Position across faces, multi setup±0.08 mm±0.04 mm
Wall thickness, over 3 mm±0.1 mm±0.05 mm
Wall thickness, under 1.5 mm±0.15 mm±0.1 mm
Surface finishRa 1.6 µmRa 0.8 µm
FinishTypical resultWhat it is for
As machinedRa 1.6 to 3.2 µmMost parts. Cheapest and often adequate.
Bead blastEven matte, Ra 1.6 to 3.2 µmUniform grey appearance, hides light tool marks.
PassivationUnchangedRemoves embedded iron and contamination. ASTM F86 is the usual reference for implants.
ElectropolishRa 0.2 to 0.4 µmMedical, vacuum and cleanliness critical parts. Removes material.
Anodize, AMS 2488 Type 2UnchangedMatte grey. Wear resistance and anti galling.
Anodize, AMS 2488 Type 3UnchangedInterference colours for colour coding and appearance.
Pickling or chemical millingDepends on removalRemoves alpha case after heat treatment or hot work in air.

Anodize colour is set by voltage and shifts with surface finish, so agree a sample when colour matters. See titanium anodizing.

Design for manufacture

Each line removes a decision a shop would otherwise make for you, and makes the quotes you get back comparable. Where the part ends up is covered by industry on the applications page.

  • Name the grade and the standard, for example Ti-6Al-4V to ASTM B348 or AMS 4928
  • Keep wall height to thickness under about 10 to 1, or expect support and staged removal in the price
  • Give inside corners the largest radius the function allows
  • Use ±0.02 mm or tighter only on fits, with ISO 2768-m on the rest
  • Say whether EDM recast and alpha case must be removed, and how it is checked
  • Put Ra only on the faces that need it and name the finish per surface
  • State thread class and whether thread milling is acceptable
  • Ask for a mill certificate to EN 10204 3.1 and lot traceability where the industry requires it

Process questions we get

Something not covered? Email .

Why is titanium slower to machine than steel?

Heat. Ti-6Al-4V conducts heat at around 7 W/m K against roughly 16 for 316L stainless and 167 for 6061 aluminium. The heat stays at the cutting edge instead of leaving with the chip, so shops run Grade 5 at around 30 to 60 m/min in milling, well below what the same machine runs in steel.

Does Grade 2 machine differently from Grade 5?

Yes. Grade 2 is softer and gummier, runs faster and is the easiest titanium to cut, but it smears if the tool is dull. Grade 5 is harder, roughly half the surface speed of Grade 2 and harder on tools. Most titanium quotes are for Grade 5.

Can titanium be wire EDM cut?

Yes. Titanium conducts, so wire and sinker EDM both work, and they suit thin slots, sharp inside corners and hard to reach features. EDM leaves a thin recast layer. On fatigue critical aerospace and implant parts, the specification usually requires that layer removed, so say on the drawing whether it applies.

Should titanium threads be tapped or thread milled?

Both are used. Titanium galls on a tap, and a broken tap in an expensive part is a scrap part, so many shops thread mill anything above small sizes. A broken thread mill usually costs a cutter rather than the part. Specify the thread class and let the shop choose the method.

Have a titanium drawing ready?